M30- Concrete Mix Design Example with Water Reducing Admixture

M30 Concrete Mix example: Let’s say we have to design a Reinforced Concrete Cement(RCC) with a slump of 100 using Cement (Specific Gravity 3.14), 20mm Sub Angular Coarse aggregate (Specific Gravity 2.45) and Zone 2 Sand (Specific Gravity 2.50) for a Moderate exposure condition. Plus We will be using a water reducing admixture

SuperPlasticiser 1% by weight of cement, 23% reduction in water achieved, SpGr 1.145

These are the steps you will take:

STEP 1 : TARGET MEAN STRENGTH

For SEVERE exposure RCC using 20mm coarse aggregate we need to atLeat use M30 Grade of concrete (As per Table 5 of IS 456 2000)

 So lets design M30

Target Mean Strength Fckt = Fck + 1.65xS

Fck = 30MPa (for M30)

Standard deviation for M30= 5.0 (Table 1 IS 10262 2009)

Fckt = Fck + 1.65×5.0

Target Mean Strength= 30+ 1.65*5.0=38

STEP 2 : CALCULATION FOR WATER CONTENT

For 20mm Aggregates MAX Water Content =186.0 (Table 2 10262 2009)

This value is for Slump within the range of 25-50

For Every 25mm increase in slump we will increase

water by 3%

Current Slump is :100 Which is :50 mm above 50mm

Increase Water Content By :6.00%

186.0+(6.00*186.00)/100 =197.16 Kg/m3

With the Admixture 23% reduction is achieved So

New Water Content = 197.16-(23/100)

Water Content = 151.81 Kg/m3

STEP 3 : SELECTION OF WATER CEMENT RATIO

For REINFORCED Concrete and SEVERE exposure

condition MAX W:C=0.45 (As per Table 5 of IS 456 2000)

STEP 4 : CALCULATION OF CEMENT CONTENT

Cement=WaterContent/w:C

Cement Content=151.81/0.45 = 337.36 Kg/m3

(As per Table 5 of IS 456 2000)Minimum Cement Content is 320

Since

337.36 >320 OK

STEP 5 : CALCULATION OF RATIO OF AGGREGATES

For 20mm Coarse and Zone 2 Fine,Volume of Coarse to Total Aggregates=0.62(Table 3 10262 2009)

This value is for w:C =0.50 our w:C=0.45

Increase Coarse Ratio by 0.01 for every decrease of 0.05 in W:C

For 0.45 there is a decrease of 0.05

So Increase Factor= 0.01

New Coarse Ratio = 0.62 + 0.01 = 0.63

Fine Agg Ratio=1-Coarse Agg Ratio=0.37

DESIGN MIX CALCULATIONS

Vol of Cement= WT OF CEMETN/(SPGR of

CEMENT*1000)=337.36/(3.14*1000)=0.11

Vol of Water=Wt of Water/1000

=151.81/1000

=0 .15

Vol of Admixture = Wt of ADM/(spgr*1000)=0.003

TOTAL AGGREGATE Vol(e) = 1-(Cement+Water+Admixture)=0.74

Wt of Coarse Aggregate=e*CoarseRatio*SPGR*1000

= 0.74*0.63*2.45*1000=1138.79 Kg/m3

Wt of Fine Aggregate=e*FineRatio*SPGR*1000

=0.74*0.37*2.50*1000=682.47 Kg/m3

M30 Concrete Mix Design Using Concrete Mix Design App
M30 Calculations Using Concrete Mix Design App

If you want a free tool with which you can create Concrete Mix Designs without doing any calculations just enter your requirements and it will do the calculations for you and it will also generate human readable calculations within seconds 

Concrete Mix Design App on Google Play: Click here to download

If you are a fresher Civil engineer looking for Job I highly recommend you read this article: How to get a construction job as a fresher civil engineer